| 1 |
| Select a Model |
|
|
|
|
|
|
|
|
0 |
1 |
1 |
1 |
1 |
|
1 |
| 120VAC - Max. Watts/Amps |
1000/8.3 |
2000/16.7 |
2000/16.7 |
2000/16.7 |
3000/25.0 |
3000/25.0 |
6500/54.7 |
| 120VAC - Rated Watts/Amps |
900/7.5 |
1600/13.3 |
1600/13.3 |
1600/13.3 |
2800/23.3 |
2600/21.7 |
5500/48.8 |
| 240VAC - Max. Watts/Amps |
N/A |
N/A |
N/A |
N/A |
N/A |
N/A |
6500/27.1 |
| 240VAC - Rated Watts/Amps |
N/A |
N/A |
N/A |
N/A |
N/A |
N/A |
5500/22.9 |
| DC - 12V - Watts/Amps |
96/8 |
96/8 |
96/8 |
96/8 |
144/12 |
100/8 |
N/A |
| 0 |
0 |
0 |
0 |
1 |
1 |
0 |
| Model |
GXH50 |
GX100 |
GX100 |
GX100 |
GX200 |
GX160 |
GX390 |
| Cylinders |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
| Displacement |
50cc |
98.5cc |
98.5cc |
98.5cc |
196cc |
163cc |
389cc |
| Valve Train |
OHV |
OHC |
OHC |
OHC |
OHV |
OHV |
OHV |
| Cooling |
Air |
Air |
Air |
Air |
Air |
Air |
Air |
| Starting |
Recoil |
Recoil |
Recoil |
Recoil |
Electric |
Recoil |
Electric |
| Noise Level @ Rated Load |
59dB |
59dB |
59dB |
59dB |
58dB |
65dB |
60dB |
| Noise Level @ 1/4 Load |
53dB |
53dB |
53dB |
53dB |
49dB |
57dB |
52dB |
| Oil Alert System |
Std. |
Std |
Std |
Std |
Std |
Std |
Std |
| Electronic Ignition |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
| Fuel Tank Capacity |
0.6 gal. |
1.1 gal. |
1.1 gal. |
1.1 gal. |
3.4 gal. |
1.56 gal. |
4.5 gal. |
| Run Time/Tank@Rated Load |
3.8 hrs. |
4.0 hrs. |
4.0 hrs. |
4.0 hrs. |
7.2 hrs. |
3.6 hrs. |
4.7 hrs. |
| Run Time/Tank@1/4 Load |
8.3 hrs. |
15.0 hrs. |
15.0 hrs. |
15.0 hrs. |
20.0 hrs. |
7.7 hrs. |
14.0 hrs. |
|
0 |
15 |
15 |
15 |
1 |
1 |
15 |
| Length |
17.7" |
20.1" |
20.1" |
20.1" |
25.8" |
24.5" |
33.5" |
| Width |
9.4" |
11.4" |
11.4" |
11.4" |
18.9" |
14.9" |
26.4" |
| Height |
15.0" |
16.7" |
16.7" |
16.7" |
22.4" |
19.3" |
27.5" |
| Dry Weight |
29 lbs. |
46.3 lbs. |
45.9 lbs. |
46.3 lbs. |
134 lbs. |
78 lbs. |
253 lbs. |
| 1 |
|
|
| 1 |
Please read the owner's manual before operating your Honda Power Equipment. Connection of a generator |
to house power requires a transfer device to avoid possible injury to power company personnel. |
Consult a qualified electrician. |